Power Limited Fire Alarm Circuits Cable Type FPLR
Product Description
Product Detail
1.Introduction of 1.Power Limited Fire Alarm Circuits Cable Type FPLR.
Power limited circuits have relatively low voltage and current,which prevents them from producing damaging amounts of fault energy.As a result,power limited circuits may have different and less stringent requirements concering over-current protection, insulation, installation,and materials than non-power-limited circuits.This range of products are designed for power limited fire alarm circuits. It help to prevent the spread of fire while fire resistant cable is able to continue supplying power to emergency circuits during fire. The cables are slow to catch fire and making it easier for people to escape in the event of a fire. The cables pass UL test 1424, and the UL vertical riser test 1666. We can supply 2 or more cores fire alarm cables.
Application :
Fire alarm cables range features a variety of cables and wires designed to ensure that emergency systems in public buildings continue to operate in some of the most extreme fire conditions. FPLR cables are rated for use in riser applications, pathways that run vertically from floor to floor. Fire alarm wiring, smoke alarms,voice communications, burglar alarms,and fire protective circuits.
2.Parameter (Specification) of 1.Power Limited Fire Alarm Circuits Cable Type FPLR..
Rating Volatge: 300V
Operating Temperature: 105℃
Standard: UL 1424, UL 1666
Part Number |
Number of Cores |
Solid Conductor Size AWG |
Nom.Drain Wire Cross Section Thickness sqmm |
Nom.Overall Diameter mm |
M.O.Q. M |
Package Details |
||
Amount of one Pallet |
Meas of (mxmxm) |
Weight of per Pallet |
||||||
H218 |
2 |
18 |
|
5.3 |
30,500 |
128 Drumx305m |
1.1x1.1x2.0 |
1600 |
H218S |
2 |
18 |
7/0.25 |
5.5 |
30,500 |
128 Drumx305m |
1.1x1.1x2.0 |
1664 |
H216 |
2 |
16 |
|
5.8 |
30,500 |
112 Drumx305m |
1.1x1.1x2.0 |
1736 |
H216S |
2 |
16 |
7/0.25 |
6.0 |
30,500 |
112 Drumx305m |
1.1x1.1x2.0 |
1792 |
H214 |
2 |
14 |
|
7.5 |
19,215 |
63 Drumx305m |
1.1x1.1x2.0 |
1575 |
H214S |
2 |
14 |
7/0.25 |
7.7 |
19,215 |
63 Drumx305m |
1.1x1.1x2.0 |
1607 |
3. Feature of 1.Power Limited Fire Alarm Circuits Cable Type FPLR..
1) Packed with UL Label and Tag.
2) Conductor: Solid bare copper.
3) Insulation color: Red (core 1), Black(core 2).
4) Drain wire(if applicable): Tinned flexible copper.
5) Wrapping tape(if applicable): Polyester tape.
6) Screen (if applicable): Aluminium/Polyester tape.
7) Sheath Color: Red
4. Details of 1.Power Limited Fire Alarm Circuits Cable Type FPLR..
1) High quality. Comply with the UL standards, each coil with UL Label and Tag.
2) 22 to 12 AWG size range, it is rated to 300 volts and has a temperature range up to 105℃.
3) Long lasting stability.
4) Brand: Haoguang. Made in China.
5. Packaging & Delivery
1) Packaging Details:
It is determined by the quantity and requirements you purchase.
We also provide plastic spool package with carton box or others besides wooden drum listed above.
Please contact us for more details.
2) Port: Ningbo,Shanghai
3)Delivery: By Sea, By Train, By Air, By express.
6. FAQ:
1)Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first beginning to the last. Because we are the factory.
2)Can I order the cable/wire which is lower than your MOQ?
First, we will check the inventory.if it is in stock, sure, it’s ok! But if it was out of stock, when your quantity is close to our MOQ, it’s OK. If it is much less than MOQ, maybe we will take it as a sample order, the price will be different.
3)Can I get a discount?
It depends on your quantity. Pls contact us for more detail information.